GPO_DATA_OUT_C Register 0x2C
Table 52. GPO_DATA_OUT_C Bit Descriptions
Bits Name R/W Description
[7: 3] Reserved.
2 GPO_19_DATA R/W 0 = low.
1 = high.
1 GPO_18_DATA R/W 0 = low.
1 = high.
0 GPO_17_DATA R/W 0 = low.
1 = high.
GPO_OUT_MODE_A Register 0x2D
Table 53. GPO_OUT_MODE_A Bit Descriptions
7 GPO_8_OUT_MODE R/W 0 = push/pull.
1 = open drain.
6 GPO_7_OUT_MODE R/W 0 = push/pull.
1 = open drain.
5 GPO_6_OUT_MODE R/W 0 = push/pull.
1 = open drain.
4 GPO_5_OUT_MODE R/W 0 = push/pull.
1 = open drain.
3 GPO_4_OUT_MODE R/W 0 = push/pull.
1 = open drain.
2 GPO_3_OUT_MODE R/W 0 = push/pull.
1 = open drain.
1 = open drain.
0 GPO_1_OUT_MODE R/W 0 = push/pull.
1 = open drain.
GPO_OUT_MODE_B Register 0x2E
Table 54. GPO_OUT_MODE_B Bit Descriptions
Bits Name R/W Description
7 GPO_16_OUT_MODE R/W 0 = push/pull.
1 = open drain.
6 GPO_15_OUT_MODE R/W 0 = push/pull.
1 = open drain.
5 GPO_14_OUT_MODE R/W 0 = push/pull.
1 = open drain.
4 GPO_13_OUT_MODE R/W 0 = push/pull.
1 = open drain.
1 = open drain.
2 GPO_11_OUT_MODE R/W 0 = push/pull.
1 = open drain.
1 GPO_10_OUT_MODE R/W 0 = push/pull.
1 = open drain.
0 GPO_9_OUT_MODE R/W 0 = push/pull.
1 = open drain.