Masterpact™ NT and NW Universal Power Circuit Breakers
Micrologic™ Electronic Trip Systems
34
05/2014
Communication Network
Masterpact NW/NT circuit breaker, and Micrologic trip unit information is available via a Modbus
network to
Powerlogic™ System Manager™ software (SMS) or other applications for reporting and recording.
Information available includes:
The Modbus circuit breaker communication feature is standard on the Micrologic P and H trip units and
available for the Micrologic A trip unit.
Modbus Circuit Breaker Communication Module (BCM)
The Modbus circuit breaker communication module (BCM) is installed in the circuit breaker and
requires a separate, isolated 24 Vdc power source. The BCM is optically coupled to the Micrologic trip
unit to ensure a high level of isolation between the trip unit and the communication network. The
Modbus BCM provides circuit breaker status via dedicated O/F (open or closed), SDE (fault tripped),
CH (spring charged), and PF (ready-to-close) switches and provides the capability of remotely
controlling the circuit breaker. It also maintains an event log of circuit breaker status containing the
number of times the circuit breaker has experienced each status position with the date and time of the
last transition. This information and the remote control capability are available to a Modbus supervisor
system via a Modbus communication network.
The following may be connected to this module:
A set of dedicated switches which read the status of the circuit breaker.
A set of “actuators” (MX/XF) to control the circuit breaker.
Circuit breaker identification and status.
Remote control of circuit breaker operation.
View and set protection function parameters.
Real-time readings.
Trip indication.
Alarm reporting.
Historical files and maintenance records.
Figure 7: Communication Network
1—Circuit breaker switches (OF, SDE, PF, and CH)
2—Cradle communication module (CCM)
3—Cradle switches (CD, CE and CT)
4—Shunt trip (MX1) and shunt close (XF)
5—Communication bus
6—Circuit breaker communication module (BCM)
7—Trip unit
Circuit Breaker
Communication Module
(BCM)